Feb 07, 2022 · One can always avoid such issues by installing the system correctly. Durability issues aside, the Amtrol BoilerMate remains a good choice for small to medium-sized households. The fact that Amtrol pioneered indirect-fired water heater technology is enough to give you a sense of security about the overall performance of the BoilerMate.
Get PriceUse this chart to select the proper circulator for your BOILERMATE ®. If a steel hydropneumatic tank is in place, AMTROL ® recommends replacing it with a properly sized EXTROL ® or Radiant EXTROL ® expansion tank. Otherwise, significant heat transfer problems can occur by causing air to be trapped in the heat exchanger. If the boiler system
Get PriceDec 14, 2019 · Amtrol boilermate hot water heating system leaking out of the bottom. Whs-120cdw. Just today and I haven't tried - Answered by a verified HVAC Technician. We use cookies to give you the best possible experience on our website.
Get PriceFeb 18, 2015 · Boilers - Home Heating Steam and Hot Water Systems - Amtrol boilermate problem - I have a 41 gallon WH 7L 7P boilermate. The temperature control has strted making a clicking sound. The control doesn't have individual buttons to raise or lower the temperature. It has one spot to push that adjusts temperature. I'm
Get PriceHVAC BRAIN's selection of Amtrol Boilermate Parts can help you repair your Amtrol Boilermate without having to replace the entire unit. If you're an HVAC professional, much of the repair cost of a boilermate unit is the costs of the Amtrol Boilermate parts that you must purchase. When you reduce the price you pay for these parts, you can cut
Get PriceDec 14, 2019 · Amtrol boilermate hot water heating system leaking out of the bottom. Whs-120cdw. Just today and I haven't tried - Answered by a verified HVAC Technician. We use cookies to give you the best possible experience on our website.
Get PriceIt was a 1984 model and had a 10 year warranty. It was out of warranty (my first boiler install was my own home, HydroPulse- electric to gas conversion). I picked up and paid for a new Boiler Mate. I also wrote to Amtrol and expained my frustration, I received a check for the wholesale amount I paid to L&H Supply.
Get PriceApr 08, 2011 · The only valves on it are down on the bottom with the spigot where the cold line is which i assume is to drain the boilermate if need be. Then on the other side there's a black dial where 120 degrees is marked between the 3 and 4 and we have it JUST BARELY above the 3 and given that the hot water at the tap runs about 160 degrees which is much closer to the boiler …
Get PriceSep 13, 2021 · Designed for today's market, the Champion Series BoilerMate is the latest addition to Amtrol's extensive lineup. With an efficient heat exchanger, simplified connections and clean design (with high gloss finish), the Champion Series is the best value in the market. Features: Includes drain and T&P valve Proven tank construction
Get PriceMar 03, 2013 · Having previously had a Boilermate 2, I'm aware that these systems can and do go wrong, and as such I'm leaning towards removal of the Boilermate. I'm happy to go with an unvented cylinder (Megaflo 170 litre has been mentioned twice, but 1 engineer said he would avoid a megaflo as they tend to go wrong after 6 years), but the quotes so far have
Get PriceGet Free Amtrol Boilermate Manual HVAC BRAIN's selection of Amtrol Boilermate Parts can help you repair your Amtrol Boilermate without having to replace the entire unit. If you're an HVAC professional, much of the repair cost of a boilermate unit is the costs of the Amtrol Boilermate parts that you must purchase.
Get PriceAug 19, 2019 · Armitrol boiler mate hot water. It tells you that your water heater called for heat for more than an hr and never got hot enough to meet the demand. multiple scenarios can cause this CAUSES -bad sensors -no hot water from boiler -bad thermal transfer -low delta T across water heater. Read full answer.
Get PriceJun 06, 2014 · You should set the Boilermate temp at whatever level works for you. The lower the setting the less fuel you'll use. We typically set water heaters between 120 & 130. Higher than 130 increases the risk of scalding and is a code violation for a plumber to set it higher than 130 unless there is a tempering valve on the hot water outlet from the tank.
Get PriceNewest Subjects. Boilermate HW Tank Hot to touch. Author: spottyj (MA) AMTROL WH-7 "Boilermate" Residential Water Heater Tank. The exterior of the tank (blue metal tank) is hot to the touch. In handling other tanks I have not noticed this, other tanks have been slightly warm. Could the tank being hot to touch indicate a failure of the liner
Get PriceFeb 02, 2022 · According to top Amtrol BoilerMate reviews, this water heater model is perfect for small to medium-sized households with its 41-gallon heating chamber. The top-mounted heat exchange coil has a 40% greater surface area than conventional indirect water heaters, allowing the appliance to heat more water and faster, too.
Get PriceAmtrol Boilermate Problem. Doityourself.com DA: 20 PA: 50 MOZ Rank: 71. Water Heaters - Amtrol Boilermate Problem - I have an Amtrol Boilermate Classic model WH-7P indirect hot water heater which is only a few years old; It was working fine until yesterday; I noticed the hot water was not so hot; I reset the switch and the lights on the Smart Controller came on for about 10 …
Get PriceAmtrol Boilermate Manual 1400 Division Road, West Warwick, RI 02893 T: 401.884.6300 F: 401.885.2567 .amtrol.com PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY INSTALLER: LEAVE THIS MANUAL WITH THE OWNER Amtrol Boilermate Manual -
Get PriceApr 10, 2021 · The water heater, if it matters, is an Amtrol 'Boiler Mate' WH-7P (41 gallons). The operating temperature at the boiler is set at 190 now, had been 220. When doing the initial repair the plumber felt the ~200F+ & ~20psi was too high and reduced it to 190F max and 15psi. Not sure if this is related to our current problems. On Liming by (mod) -
Get PriceAug 19, 2019 · Armitrol boiler mate hot water. It tells you that your water heater called for heat for more than an hr and never got hot enough to meet the demand. multiple scenarios can cause this CAUSES -bad sensors -no hot water from boiler -bad thermal transfer -low delta T across water heater. Read full answer.
Get PriceAmtrol Boilermate Problem. Doityourself.com DA: 20 PA: 50 MOZ Rank: 70. I have an Amtrol Boilermate Classic model WH-7P indirect hot water heater which is only a few years old; It was working fine until yesterday; I noticed the hot water was not so hot; I reset the switch and the lights on the Smart Controller came on for about 10 seconds and pulsed and shut off.
Get PriceOtherwise, significant heat transfer problems can occur by causing air to be trapped in the heat exchanger. If the boiler system has a diaphragm expansion tank and the boiler temperatures are being changed, resize the expansion tank. If installing on city water supply, a properly sized thermal expansion tank is required with the water
Get PriceFeb 27, 2017 · Boilers - Home Heating Steam and Hot Water Systems - Amtrol WH-7L Problem - wrong time for this to happen - Very cold and snow for the next 24 hours, and now it looks like I might have a water heater problem. With my next oil delivery a few days off, I've had the thermostat lower than usual. So, as expected, the boiler
Get PriceOct 19, 2009 · Amtrol Boilermate Issues. We had our 3rd Amtrol Boilermate start to leak in less than 10 years. They have replaced the system 2x, only to have it start to leak again. The last system started to leak in less than 1 year. This last time, the Extrol Tank failed and now is …
Get PriceAmtrol Boilermate Problem - DoItYourself.com Community Forums
Get PriceAug 19, 2019 · Armitrol boiler mate hot water. It tells you that your water heater called for heat for more than an hr and never got hot enough to meet the demand. multiple scenarios can cause this CAUSES -bad sensors -no hot water from boiler -bad thermal transfer -low delta T across water heater. Read full answer.
Get PriceJul 03, 2007 · BoilerMate, etc. Normally the only things you need to do to the BoilerMate are: Once a month open the bottom drain valve & drain off a couple of gallons or until the water is clear. There should be a temperature & pressure relief saftey valve at or near the top of the tank which should be opened once a month by lifting the little lever.
Get PriceCheck the top of the tank near the relief valve, it should be cold. If you feel hot around the top of the tank, near the relief valve, the liner has failed and the water is soaking into the insulation. Only a matter of time before it rust through the steel tank. Another common problem with these tanks.
Get PriceAmtrol 2704E76 - 41 Gallon WH-7C BoilerMate Classic Series Indirect-Fired Water Heater - The Classic Series BoilerMate is the indirect water heater that started it all. With three decades of proven performance and reliability, the Classic Series remains the industry standard. <br Features: Commercial heat exchanger Includes drain and T&P valve
Get PriceFind helpful customer reviews and review ratings for Amtrol BoilerMate WH-41Z Indirect-Fired Hot Water Heater, Gray, 41 Gal, 3/4" NPT at Amazon.com. Read honest and unbiased product reviews from our users.
Get PriceUnsolved problems for amtrol wh7l er2 question. Get free help, tips & support from top experts on amtrol wh7l er2 related issues. Search Fixya Clicking sound from amtrol boilermate WH7l smart control. Read full answer. Be the first to answer Feb 09, 2013 • Water Heaters. 0 answers.
Get PriceSep 29, 2019 · Amtrol 2704Z37-6 - 41 Gallon WH-41Z BoilerMate Classic Series Indirect-Fired Water Heater - The Classic Series BoilerMate is the indirect water heater that started it all. With three decades of proven performance and reliability, the Classic Series remains the industry standard. Features: Includes drain and T&P valve Durable triple shell
Get PriceAmtrol Boilermate Problem - DoItYourself.com Community Forums
Get PriceJan 26, 2006 · Hi all, We just had a Boiler Mate Classic installed for our potable hot water source (vs. tankless coil in the oil fired boiler). Wondering how the heck we adjust the temperature. Installer put it at the suggested start of 120 and it needs to be higher. We are looking at the dial and there are 6 rectangles in a circle with numbers 1 - 6 in them and right between the 3 and 4 …
Get PriceJul 03, 2007 · BoilerMate, etc. Normally the only things you need to do to the BoilerMate are: Once a month open the bottom drain valve & drain off a couple of gallons or until the water is clear. There should be a temperature & pressure relief saftey valve at or near the top of the tank which should be opened once a month by lifting the little lever.
Get PriceThis manual may become out-of-date by later amendments. Check our web site, .amtrol.com or ask your AMTROL supplier for any updates relating to your product. Our goal is to ensure you are fully satisfied with your new BOILER MATE ™. If any questions or concerns arise, call Technical Service at 401-535-1216.
Get PriceJan 04, 2009 · we changed out 2 boilers today in an apartment house both had old weil mclain boilers and amtrol boilermates the boilermate were connected to the zr trminal on the old boilers then new boilers have a honeywell 8148A and dont have the zr so we connected to the B terminal.One of the boilers works fine the other when the boilermate calls to start up the boiler, …
Get PriceAmtrol Boilermate Problem - DoItYourself.com Community Forums
Get PriceJun 08, 2015 · I have the AMTROL WH-7P BOILER MATE Hot Water Maker which I installed in 1993/94. It has the manual/rotary thermostat control. My system consists of a Well-McClain P-WGO-4 series 3 boiler; Honeywell L8148A Aquastat; Taco SR-504 (four zone) switching relay; a Honeywell R8184G 4009 Intermittent Ignition Oil Primary Switch; and four Taco 007 circulators …
Get PriceFeb 01, 2016 · Even Amtrol makes their commercial units with SS. The "largest" or more accurately, most common cause of failure is particular to the manufacturer and model. All indirect water heaters will generally last 30 years. About three times as long as a gas-fired tank water heater and twice that of the average tank-less.
Get PriceMy BoilerMate 60 gallon tank failed after only 2 years. What is most infuriating, is that it failed due to the fact that Amtrol chose to use regular steel isntead of stainless steel for a critical but small component of the tank.
Get PriceDec 23, 2021 · I have one that's about 10 years old. No issues so far. The reason I like it is just another zone on the boiler, no exhaust vent, the tank is lined so water isn't sitting in a steel tank and rusting out and because we are on a well, many people with traditional hot water heaters have issues with the anode rod causing the water to smell bad.
Get PriceJun 08, 2015 · I have the AMTROL WH-7P BOILER MATE Hot Water Maker which I installed in 1993/94. It has the manual/rotary thermostat control. My system consists of a Well-McClain P-WGO-4 series 3 boiler; Honeywell L8148A Aquastat; Taco SR-504 (four zone) switching relay; a Honeywell R8184G 4009 Intermittent Ignition Oil Primary Switch; and four Taco 007 circulators …
Get PriceJan 25, 2012 · I'm considering replacing my Amtrol Boilermate hot water tank with a tankless LP fired hot water system. I use roughly 350 gallons of oil per year or about $1000 to keep water heated until needed. I would like to cut that cost in half or better if possible. Does anyone have any recommendations
Get PriceThis may require moving the heating circulator off the boiler tapping on packaged boilers. Failure to do so will result in overheating and tank damage when the heating system is in operation." Our oil hot water boiler has two return circulators on the return, one for the baseboard heat return, the other for the boilermate's return.
Get PriceNov 09, 2021 · Amtrol boiler mate top flange weeping water between flange and tank. does flange need to be snug against top of tank, - Answered by a verified HVAC Technician. We use cookies to give you the best possible experience on our website. I am having problems with the pressure of my gold CGi Series.
Get Price